Chapter 3 Functional Descriptions
11
RAID (0+1) Disk Striping with Mirroring
Block 1
Block 2
Block 3
Block 4
Block 5
Block 6
Block 7
Block 8
.
.
Block 1
Block 3
Block 5
Block 7
Block 2
Block 4
Block 6
Block 8
Striping
Logical Drive
Physical Disks
.
.
.
.
Mirror 1
Mirror 3
Mirror 5
Mirror 7
Mirror 2
Mirror 4
Mirror 6
Mirror 8
.
.
.
.
Striping
Mirror
RAID (0+1)
Minimum Disks required
4
Capacity
N/2
Redundancy
Yes
RAID (0+1) combines RAID 0 and RAID 1 - Mirroring and Striping.
RAID (0+1) allows multiple drive failure because of the full redundancy
of the hard drives. If there are more than two hard drives assigned to
perform RAID 1, RAID (0+1) will be performed automatically.
"RAID (0+1)" will not appear in the list of RAID
levels supported by the controller. If you wish
to perform RAID 1, the controller will determine
whether to perform RAID 1 or RAID (0+1). This
will depend on the drive number that has been
selected for the logical drive.