AC S.A. All rights reserved. Copying, publishing, distribution and any usage of the full or partial data included in the herewith document, particularly pictures, drawings, illustrations, trade marks etc. is
strictly prohibited under the law.
Page 52 of 54
Figure 2.3.2
LED-401 set-up window
The controller remembers the most recent fuel settings applicable prior to cutting off the
supply voltage with the key.
2.3.2
LED-500 switchboard
Figure
2.3.3
LED-500 switchboard view
LED-500 switchboard features the following elements:
LED line –
shows current LPG level in the tank. Four green LEDs indicate a full tank; a red
LED indicates “reserve”,
Touch-button (recess in the center of the switch) –
enables fuel switchover,
STAG logo (status LED) –
indicates the current mode of operation:
•
darkened – the vehicle is running on petrol;
•
flashes slowly (once per second) – the engine is running on petrol, once the set
parameters have been achieved, the system will automatically switchover to LPG;
•
flashes normally (twice per second) with no sound signals – the system is switching
over to LPG; this can last up to 10 seconds depending on the current parameters of the
engine;
•
backlit in white – the vehicle is running on LPG;