AC S.A. All rights reserved. Copying, publishing, distribution and any usage of the full or partial data included in the herewith document, particularly pictures, drawings, illustrations, trade marks etc. is
strictly prohibited under the law.
Page 17 of 54
1.3.7
Installation of injection nozzles and manifold absolute pressure nozzles
Picture 1.3.33
Location for installation of nozzles
in the manifold (view from the outside)
Picture 1.3.34
Location for installation of nozzles (view
from the inside of the manifold conduit)
), it is necessary to remove the inlet manifold. Orifices should be
drilled as close to the engine head as possible. Mount nipples in such a manner, as to makes sure they
point to the suction valves, and secure them against unscrewing. Connect injection tubes to the nipples
and secure them with a metal clamp.
Mount the injector on supports and connect it to the injection tubes. Subsequently, fit the supply tube
as well as the pressure measuring tube. Connect the wiring harness to the injectors, while observing the
order specified in the
NOTE! Nozzle sizes for particular types of engines have been specified in the
The manifold absolute pressure nozzle should be installed in the shared part of the inlet manifold
(downstream the throttle).
Picture 1.3.35
A manifold absolute pressure nozzle fitted in the manifold