PROBOIL.2X user & installation guide v1e-2
7
Periods of non-use
If the product is going to remain unused and unattended for example you are away for a few days, we recommend
changing the temperature to its minimum setting 75°C, this will reduce the energy consumption and encourage sanitary
conditions.
⚠
WARNING
:
If you are not using the product and leaving it unattended for a period longer than 1
week you should turn the boiler into standby mode (see using the product section), do not turn off
the power at the mains socket as this will reset the filter counter.
You may also consider closing your mains stop cock to prevent flood damage from any of the water using appliances in
your household.
Upon returning after an extended period of absence with the heating power off you must re-sanitise the boiler and
connections by following the steps below.
1.
Turn on both the water supply (if previously isolated) and the boiler
2.
Adjust the boiler temperature to 98°C
3.
Wait for the boiler to display “READY”
4.
Wait a further 10 minutes
5.
Dispense the entire contents of the boiler as normal until the heated water stream is entirely cold then allow it to
continue to run for 5 minutes.
6.
Turn on the standard cold tap and run this for 5 minutes also at the same time
7.
Turn off the heated water and cold water taps
8.
Allow the boiler to reheat fully to 98°C and display “ready” before use
Aesthetic cleaning
Use of any cleaners with acids, abrasives, alkaline or organic solvents, on any part of the product
can result in deterioration of the components and will void the warranty. Clean the product only with
a mild dish soap and a damp non-abrasive cloth.
⚠
WARNING
:
Do not use any excess water or steam jet when cleaning this appliance.
⚠
WARNING
:
Cleaning and user maintenance shall not be performed by children without
supervision.
⚠
WARNING
:
Disconnect the appliance from the power outlet before cleaning, allow the product
to cool before cleaning and take care of any surfaces or components that may still be hot.
You should ensure the boiler is and tap aerator are both free of limescale to ensure continuous
safe and energy efficient usage of this product. Advice on sterilisation and descaling are covered
separately within this guide.