5)
Firmly pull the silicone rubber high
temperature output hose
(K)
off from the
red outlet wing nut
(J)
connector.
6)
Lift up then pull the boiler to unhook the
boiler from its keyhole slots away from
the wall it is mounted on.
7)
Unscrew and detach the red outlet wing
nut
(J)
connector from the top of the
boiler
(C)
.
8)
If the 3/8” rubber seal
(I)
becomes
detached from the red outlet wing nut
(J)
connector then reinsert it the seal inside
connector
(J).
9)
Remove the inlet meshed filter seal
(H)
from the boiler inlet
(B)
or inlet adaptor
(G)
, rinse the washer in cold water, and
use a toothbrush to clean any debris
from it. If meshed seal
(H)
is compressed
inside inlet
(B)
or adaptor
(G)
then use a
cocktail stick (or similar) to remove it.
9.
Whilst taking care lift the PROBOIL.2X
(A)
unit out from the cabinet and place it on the countertop.
10.
Each bottle of PROBOIL descaling
solution contains 200ml of descaling
solution, one bottle should be enough to
descale the tank, however if you believe
the tank to be heavily scaled then use
both the 200ml bottles supplied.
11.
Tip the boiler upside down so the boilers
centre outlet
(C)
is over the sink, you
must empty the boiler as much as
possible of water and any debris, tip the
boiler back and forth to hear how much
water remains inside if you are unsure.
You can empty the boiler faster from the outlet
(C)
by
depressing the centre of the check valve insert found in the boiler
inlet
(B)
whilst the boiler is upside down.
12.
Shake the descaler bottle(s) thoroughly.
13.
Cut the top from the bottle nozzle(s)
using sharp scissors.
14.
Carefully squeeze the entire contents of
the bottle(s) into the outlet
(C)
of the