PROBOIL.2X user & installation guide v1e-2
23
98°C water does not start the instant the 98°C
handle is turned on.
It is normal for a short delay after the handle is turned on for
water to start flowing as the tap empties partly after each use.
⚠
Water splashes sideways or irregularly
from the spout end
The spout aerator may be blocked or calcified, see “descaling-
aerator” section for more detail.
⚠
Water flow rate is faster than expected
or is splashing
The aerator on the tap could be partly blocked with debris or
calcified:
follow the aerator descale procedure in this manual.
Your incoming cold water pressure could be too high:
test your
incoming cold water pressure and compare it to the recommended
and maximum required pressures, install a pressure reducing valve
to your cold water mains supply if needed.
Follow the “Using the product safely” section of this manual: turn
on the 98°C water handle only partly during use.
1.3.5
Leaking from the boiler
Issue description:
Possible issue & solutions:
⚠
Water is leaking from the boiler.
The boiler could be leaking from between the inlet adaptor and
the boiler inlet:
Remove the inlet adaptor (G) and check that the
internal flat rubber seal is present internally and that rubber
meshed seal (H) is also present, undamaged and seated correctly.
When reconnecting the inlet adaptor (G)
do not overtighten
.
The boiler could be leaking from between the outlet adaptor and
the boiler outlet:
Remove the outlet adaptor (J) and check that
“flat” rubber seal (I) is present, undamaged and seated correctly.
When reconnecting the adaptor (J)
do not overtighten
.
⚠
The silicone high temperature hose (K)
“blows” off the outlet wingnut adaptor (J) or
3/8” male tap connector (L) when the tap
boiled water handle is turned on.
The steel braided flexible hoses attached to the tap have been
installed incorrectly: T
o confirm disconnect the silicone outlet
tube (K) outlet wingnut adaptor (J), turn the 98° tap handle slowly
part on. If cold water comes out of the
silicone high temperature
hose (K), the installation is incorrect, turn off the boiler power, the
installation must be checked and corrected before further use.
The silicone hose from the boiler or the high temperature braided
steel flexible hose in the tap is kinked:
check the hose for kinks
and or damage, remove and reattach without any kinks.
⚠
Note: If your experience an issue that is not listed here or corrected by the following the troubleshooting guide,
please follow the steps below:
1.
Switch the boiler off.
2.
Isolate the mains water to the product
3.
Contact the service number on top of the boiler
⚠
Other than as described in the maintenance, care, descaling, troubleshooting and cleaning sections of this user
guide, this appliance must not be opened, serviced or repaired by anyone other than an authorised service agent.