ABIMIG
®
A / A T / W / W T / MT
6 Putting out of operation
EN
-
45
6 Putting out of operation
1
Stop the welding process.
2
Wait for the gas post-flow time to pass then switch off the welding power
source.
3
Close the valve on the shielding gas cylinder.
4
Switch off the cooling unit.
7 Maintenance and cleaning
7.1
Annual maintenance by an electrician
► Have all components (welding torch, cable assembly, spare and
wear parts) inspected and cleaned by an electrician trained by
ABICOR BINZEL. Replace if necessary.
► In the case of extremely frequent use and/or very high current intensity
and/or evident wear, shorten the interval.
7.2
Replacing wear parts, Fig. 5/Fig. 6
► Order data and part numbers for the equipment parts and wear parts
can be found in the current order documents.
► Equip the welding torch neck with wear parts in line with the
welding task.
7.3
Cleaning the cable assembly
1
Replace any damaged, deformed or worn parts.
2
Lay out the cable assembly straight.
3
On the central connector: Unscrew the nut.
4
Air blast the wire conduit from both sides with compressed air.
5.4 Connecting the Bikox /cable assembly on page EN
NOTICE
Material damage due to overheating
Liquid-cooled cable assemblies may start leaking if overheated.
► Allow the cooling unit to continue running for approx. 5 min. after the welding process.
WARNING
Risk of injury from hot coolant
If the coolant hose is disconnected during or straight after operation, coolant can spray out and burn or irritate skin and mucous membranes.
► Allow the welding torch and coolant to cool down.
► Check and wear your personal protective equipment.
WARNING
Risk of burns from hot surface
Welding torches become very hot during welding. They could cause major burns.
► Allow welding torches to cool down after welding.
► Wear the correct protective gloves.
CAUTION
Risk of injury due to unexpected start
If the device is energised during maintenance, cleaning or disassembly work, parts can unexpectedly start up and cause injuries.
► Switch off the device.
► Close off all supply lines.
► Disconnect the electrical power supply.
NOTICE
Material damage through the use of unsuitable wear parts and mounting tools
The use of wear parts from other manufacturers and the improper installation of wear parts can cause material damage to the welding torch and impair work
results.
► Only use original ABICOR BINZEL wear parts.
► Use the ABICOR BINZEL switch key wrench to attach and remove wear parts.
► Ensure that the welding-torch-specific wear parts are correctly assigned.
► Ensure that the parts are installed in the correct order.
WARNING
Risk of injury caused by parts swirling around
► When air blasting with compressed air, device parts can come away and cause serious injuries.
► When air blasting the wire guide, wear suitable protective clothing, in particular safety goggles.