22-22
Art: 714384-00D
Rev. Date: 07/18/06
Delete Instrument
Click the Location/Method for the instrument to be deleted and then the serial
number of the instrument to be deleted. Click
instrument
delete... from the
menu or click
delete inst. in the toolbar.
Move Instrument
Click the Location/Method for the instrument to be moved and then on the serial
number of the instrument to be moved. Click
instrument
move... from the
menu or click
move inst. in the toolbar. Select the new location from the drop
down list or type in a new location.
Find Instrument
Click
instrument
find... from the menu or click find... in the toolbar. Enter
the serial number of the instrument and select the Method from the drop down
list.
Edit Instrument Comment
Click the instrument serial number, click
instrument
edit Comment from the
menu or click
edit inst. in the toolbar. Enter a comment of up to 16 characters.
Change Current Instrument Setttings
reporting: Click the instrument serial number. Click instrument
Current
instrument
Change reporting from the menu or click the down arrow next
to
Current inst. and then reporting in the toolbar to toggle between download
and
Assignment.
in use: Click the instrument serial number. Click instrument
Current
instrument
toggle in use from the menu or click the down arrow next to
Current inst. and then in use in the toolbar to check (in use) or un-check (out of
use) the analyzer in the In Use column.
Instruments that are not checked “In Use” do not have a download criteria
applied to them. You would use this for instruments you do not expect to be
downloaded. When an analyzer that is not marked “in use” downloads, it is set
back in use and the download criteria is applied.
monitoring: Click the instrument serial number. Click instrument
Current
instrument
Change monitoring from the menu or click the down arrow next
to
Current inst. and then monitoring in the toolbar to check or un-check the
analyzer in the Monitoring column.
Add Instrument Note
Click
instrument
Add note... from the menu or click Add note in the toolbar.
A note of up to 50 characters can be entered. The note will appear as a Log
Entry in the Instrument Log tab page.
Change Download Monitoring Criteria
Compliance to download policy can be monitored by the CDS program. Click
on the Location/Method. Click on
instrument
download Criteria... from the
menu or click
Criteria in the toolbar. Enter the required download interval. An
interval of up to 1000 hours is allowed.
Compliance with the criteria can be observed by checking the Highlight
Download Status check box or by going to the Download Monitor. Individual
Download criteria can be set for each location and method pair.
Содержание i-STAT 1
Страница 1: ...i STAT 1 System Manual Rev Date 20 Jan 12 Art 714336 00L ...
Страница 18: ...1 8 Art 714363 00U Rev Date 02 Aug 12 ...
Страница 44: ......
Страница 90: ......
Страница 106: ...9 12 Art 714371 00E Rev Date 06 Aug 12 ...
Страница 162: ......
Страница 166: ...Art 730292 00A Rev Date 20 Feb 12 4 ...
Страница 176: ...10 10 Art 714372 00L Rev Date 30 Jul 12 ...
Страница 182: ...11 6 Art 714373 00F Rev Date 17 Jan 11 ...
Страница 184: ...12 2 Art 714374 00J Rev Date 25 Aug 11 ...
Страница 185: ...Art 714374 00J Rev Date 25 Aug 11 12 3 ...
Страница 186: ...12 4 Art 714374 00J Rev Date 25 Aug 11 ...
Страница 187: ...Art 714374 00J Rev Date 25 Aug 11 12 5 ...
Страница 192: ......
Страница 194: ......
Страница 214: ...14 20 Art 714376 00M Rev Date 31 Jan 12 ...
Страница 216: ...14 22 Art 714376 00M Rev Date 31 Jan 12 ...
Страница 218: ...14 24 Art 714376 00M Rev Date 31 Jan 12 ...
Страница 220: ...14 26 Art 714376 00M Rev Date 31 Jan 12 ...
Страница 222: ...14 28 Art 714376 00M Rev Date 31 Jan 12 ...
Страница 224: ...14 30 Art 714376 00M Rev Date 31 Jan 12 ...
Страница 226: ......
Страница 236: ......
Страница 252: ...17 4 Art 714379 00F Rev Date 18 Jul 12 ...
Страница 254: ......
Страница 294: ...Art 725768 00E Rev Date 04 Jan 12 20 ...
Страница 336: ...22 2 Art 714384 00D Rev Date 07 18 06 ...
Страница 342: ...22 8 Art 714384 00D Rev Date 07 18 06 ...
Страница 348: ...22 14 Art 714384 00D Rev Date 07 18 06 ...
Страница 352: ...22 18 Art 714384 00D Rev Date 07 18 06 ...
Страница 364: ...22 30 Art 714384 00D Rev Date 07 18 06 ...
Страница 384: ...22 50 Art 714384 00D Rev Date 07 18 06 ...
Страница 404: ...22 70 Art 714384 00D Rev Date 07 18 06 ...
Страница 488: ...Kaolin ACT 4 Art 715878 00M Rev Date 31 Jan 12 ...
Страница 536: ......
Страница 556: ...Art 714261 00E Rev Date 10 Jan 11 8 ...
Страница 560: ...Art 716240 00D Rev Date 03 Mar 10 4 ...
Страница 572: ...Art 715617 00D Rev Date 06 11 08 ...
Страница 578: ...Art 714547 00F Rev Date 06 11 08 ...
Страница 590: ...Art 720735 00B Rev Date 06 11 08 ...
Страница 592: ...Art 721106 00B Rev Date 06 11 08 ...
Страница 598: ...Art 722831 00A Rev Date 19 Feb 09 ...
Страница 610: ...Art 720654 00B Rev Date 06 11 08 ...
Страница 614: ...Art 721317 00D Rev Date 13 Aug 12 4 ...
Страница 616: ...Art 725703 00A Rev Date 08 Mar 10 2 ...
Страница 618: ...Art 721296 00A Rev Date 07 16 08 ...
Страница 620: ...REV DATE 16 Oct 12 ART 714446 00L ...
Страница 627: ...PROCEDURE MANUAL FOR THE i STAT SYSTEM 6 REV DATE 16 Oct 12 ART 714446 00L ...
Страница 628: ...PROCEDURE MANUAL FOR THE i STAT SYSTEM 7 REV DATE 16 Oct 12 ART 714446 00L ...
Страница 629: ...PROCEDURE MANUAL FOR THE i STAT SYSTEM 8 REV DATE 16 Oct 12 ART 714446 00L ...
Страница 630: ...PROCEDURE MANUAL FOR THE i STAT SYSTEM 9 REV DATE 16 Oct 12 ART 714446 00L ...
Страница 658: ......