BUSCH-/ABB-SECURE@HOME
2CSM600727D0901
59/74
The events that can be programmed are:
Event
Type of sending
Filter
Intrusion
VOICE / SMS
Alarm zone
Tampering
VOICE / SMS
Alarm zone
Central unit Tampering
VOICE / SMS
Burglar
VOICE / SMS
Assistance
VOICE / SMS
Fire
VOICE / SMS
Technological zone
Gas
VOICE / SMS
Technological zone
Flooding
VOICE / SMS
Technical support(***)
VOICE / SMS
No 230V (*)
VOICE / SMS
230V return
VOICE / SMS
Technological
VOICE / SMS
Technological zone
Contact ON
VOICE / SMS
Technological zone
Periodic GSM inspections
VOICE (**)
Low Battery
VOICE / SMS
Central unit Battery
VOICE / SMS
Input
VOICE / SMS
Disarming
VOICE / SMS
Jamming
VOICE / SMS
Hardware Fault
VOICE / SMS
Radio Fault
VOICE / SMS
VOICE indicates a voice message, SMS indicates a text message.
(*) after 15 minutes of continuous power outage (maximum delayed allowed under EN50131-1 and
EN50131-3 standards is 60 min.)
(**) Carried out once a day (at 18:00). This event must be enabled on at least one of the programmed
telephone numbers. If this is not set, the system will not comply with EN50136-1.
(***) The Technical Assistance event is generated when there is a supervision failure by a sensor /
alarm / repeater installed in the system.
WARNING!
SMS delivery time is determined by the telephone operator network service. As
such, there is no guarantee that it will be delivered promptly.