12.4
Programming external sirens
The system can handle up to 4 sirens. To programme the sirens:
1. Access the Programming menu and log in as a level 3 user.
2. Select the "system devices" icon
3. Press 2 External sirens and the following video will appear:
4. Press Ok. The central unit is waiting for the Service PIN: press the Service PIN, consulting
the siren manual.
12.4.1
Possible parameters
-
Supervision
. Allows you to select the frequency at which the central unit checks that
the siren is working. (No/15/45). The parameter set is the time interval between one
check and another.
-
Exclude
: Yes/
No.
Enables exclusion of the external siren
-
Anti-masking
:
Yes
/No. enables the anti-jamming protection to be excluded.
-
Tamper
:
Yes
/No. When set to YES, the Siren sounds in the event of central unit
tampering (or jamming), otherwise this is ignored.
-
Technological Alarm:
Yes
/No. When set to NO, the technological alarms will not
sound, even if the parameters in the Alarms - Technological type field are set.
12.4.2
Zones Filters
Allows customised filters to be set for the siren, or the zone (or zones) where the siren is
assigned, to for the conditions to be set under which the alarm siren sounds. The options are:
All zones, or a sub-set of zones.
No Device
New Device
Address
Xxxxxxx
Supervision
<15 >
Exclude:
<NO
Anti-masking
Yes