ABB | SACE Tmax XT
6 | © 2019 ABB | 1SDH002039A1002 - ECN000093027 - Rev. A
Overview of Ekip Touch | 1 - General characteristics
Overview of Ekip Touch
1 - General characteristics
Families
SACE Tmax XT5 can be configured to operate with two Trip unit families:
• Ekip Dip with interface via dip-switches
• Ekip Touch with touchscreen display
Both families provide protection and measuring functions related to signals from the installation and are
available in different models and versions.
There are six Ekip Touch models available:
• Ekip Touch
• Ekip Touch Measuring
• Ekip Hi-Touch
• Ekip G Touch
• Ekip M Touch
• Ekip G-Hi Touch
As mentioned previously, a description of Ekip Touch is given in this manual;consult the
Installation Instructions
for a description of Ekip Dip; references are given on page 4
Main functions
The Ekip Touch Trip unit provides the following functions:
1.
Measurement
: measurement of different quantities, such as: current, voltage, power, energy
2.
Protection
: depending on the measurements made and the parameters configured by the user, the
Trip unit checks for the presence of alarms and commands circuit-breaker opening if necessary
3.
Signalling
: management of contacts and communication networks to optimize plant efficiency,
communication among different CB and other functions
The Ekip Touch functions are provided both by means of transducers and actuators inside the circuit-breaker,
and by means of a vast range of external accessories
Presentation
Figure 2
Ekip Touch has a touchscreen display (
1
) for accessing the configuration menus and checking parameters,
measurements and information (page 23).
The nominal size of the Rating plug (
2
) can be checked on the front (page 127) and access the battery
compartment (
4
).
Connections to the internal and external electronic accessories are in the internal terminal box (
3
) (page 13
for an overview of the electronic accessories, refer to the Technical catalog and Circuit diagrams for all the
other accessories).
The external connectors for zone selectivity are on the back (
5
) (page 72) and, with 3P CB, for the
External
neutral
sensor (page 200).