Recorded data
Event (R)
Value
n
Channel 1
n-1
Channel 2
n-2
Channel 3
n-3
Channel 4
n-4
Channel 5
Pickup duration
of element 49/
38-1, trip
1V19
2V19
3V19
4V19
5V19
0...100%
Pickup duration
of element 49/
38-2, alarm
1V20
2V20
3V20
4V20
5V20
0...100%
Pickup duration
of element 49/
38-2, trip
1V21
2V21
3V21
4V21
5V21
0...100%
Pickup duration,
element (48/14
PICKUP)
2
x (48/
14 TDLY) or 48/
14
1V22
2V22
3V22
4V22
5V22
0...100%
Pickup duration,
element 50P
1V23
2V23
3V23
4V23
5V23
0...100%
Pickup duration,
element 46
1V24
2V24
3V24
4V24
5V24
0...100%
Pickup duration,
element 51N
1V25
2V25
3V25
4V25
5V25
0...100%
Pickup duration,
element 37
1V26
2V26
3V26
4V26
5V26
0...100%
Time stamp of
the recorded
data, date
1V27
2V27
3V27
4V27
5V27
YY-MM-DD
Time stamp of
the recorded
data, time
1V28
2V28
3V28
4V28
5V28
HH.MM; SS.sss
Disturbance recorder
Table 5.1.15.-4
Parameters for the disturbance recorder
Description
Parameter (channel 0)
R, W
Value
Remote triggering
M1
a)
W
1
Clear recorder memory
M2
W
1
Sampling rate
M15
b)
R, W
800/960 Hz
400/480 Hz
50/60 Hz
Station identification/unit number
M18
R, W
0...9999
Rated frequency
M19
R
50 or 60 Hz
Name of the motor drive
M20
R, W
Max 16 characters
Digital channel texts
M40...M47
R
-
Analog channel texts
M60...M63
R
-
Analog channel conversion factor and unit
for I
a
, I
b
and I
c
M80
c)d)
R, W
Factor 0...65535, unit (A,
kA), e.g. 10,kA
M81 and
R
M82
R
94
REM 610
REM 610
Motor Protection Relay
Technical Reference Manual - ANSI Version
1MRS755537
Содержание REM 610
Страница 1: ...Motor Protection Relay REM 610 REM 610 Technical Reference Manual ANSI Version ...
Страница 2: ......
Страница 6: ...6 ...
Страница 8: ...8 ...
Страница 12: ...12 ...
Страница 124: ...124 ...
Страница 144: ...144 ...
Страница 154: ...154 ...
Страница 157: ......