Note
External emergency stop switches are required in below cases in accordance
with applicable standards:
•
FlexPendant is hot swapped.
•
FlexPendant is placed in its holder.
2
4
6
1
3
5
8
10
12
7
9
11
14
16
13
15
xx1800000553
Description
Pin
Description
Pin
24V_CH1
16
0V_CH1_CH2
15
AS1+
14
AS1-
13
AS2+
12
AS2-
11
24V_CH2
10
0V_CH1_CH2
9
24V_CH1
8
0V_CH1_CH2
7
ES1+
6
ES1-
5
ES2+
4
ES2-
3
24V_CH2
2
0V_CH1_CH2
1
The automatic stop and external emergency stop interfaces located in X14 are
dual-channel safety inputs.
Each channel has 4 pins on the connectors, and the pin descriptions are shown
in the following table.
Description
Pin
24 V power supplied by robot controller for stop switch use only. It
must not be used for any other functions.
24V_CH1/2
Safety loop high side of automatic stop input.
AS1+/ AS2+
Safety loop low side of automatic stop input.
AS1-/ AS2-
Safety loop high side of external emergency stop input.
ES1+/ ES2+
Safety loop low side of external emergency stop input.
ES1-/ ES2-
24V power reference ground.
0V_CH1_CH2
Continues on next page
Product manual - OmniCore C90XT
93
3HAC073706-001 Revision: D
© Copyright 2020-2021 ABB. All rights reserved.
3 Installation and commissioning
3.5.9 Descriptions for connectors
Continued
Содержание OmniCore C90XT
Страница 1: ...ROBOTICS Product manual OmniCore C90XT ...
Страница 2: ...Trace back information Workspace 21A version a14 Checked in 2021 03 30 Skribenta version 5 4 005 ...
Страница 50: ...This page is intentionally left blank ...
Страница 350: ...This page is intentionally left blank ...
Страница 354: ...This page is intentionally left blank ...
Страница 412: ...This page is intentionally left blank ...
Страница 444: ...This page is intentionally left blank ...
Страница 448: ......
Страница 449: ......