Removing the axis computer
Preparations
Note/Illustration
Action
DANGER
Before doing any work inside the cabinet,
disconnect the mains power. For more
information, see
1
.
Open the door.
2
Location of wrist strap button:
ELECTROSTATIC DISCHARGE
(ESD)
The unit is sensitive to ESD. Before
handling the unit read the safety inform-
ation in section
3
xx1900001446
Removing the axis computer from the cabinet
Note/Illustration
Action
Disconnect:
•
K6.X11 - A1.X3
•
K6.X2 - A2.X9
•
K6.X1 - K2.X3.
1
Loosen the screw and disconnect:
•
K6.X4, K6.X5 - SMB.
2
Continues on next page
176
Product manual - OmniCore C90XT
3HAC073706-001 Revision: D