Note/Illustration
Action
Disconnect:
•
X0 - Q0.
X0 - A1.X1.
•
PE.3 & PE.4.
2
xx1900001918
Remove the attachment screws.
3
Push the power inlet into the cabinet.
4
Take the power inlet out.
5
Refitting the power inlet
Refitting the power inlet
Note/Illustration
Action
DANGER
Before doing any work inside the cabinet,
disconnect the mains power. For more
information, see
1
Location of wrist strap button:
ELECTROSTATIC DISCHARGE
(ESD)
The unit is sensitive to ESD. Before
handling the unit read the safety inform-
ation in section
2
xx1900001446
Continues on next page
304
Product manual - OmniCore C90XT
3HAC073706-001 Revision: D
© Copyright 2020-2021 ABB. All rights reserved.
5 Repair
5.3.4 Replacing the power inlet
Continued