Note
Action
Use a multimeter and insulating gloves.
Measure the AC input voltage.
•
A1.X1 - A1.K1
6
The AC input voltage should be 230 V.
Make sure that connector X1 is connected
properly on both ends.
•
If the input voltage is normal, proceed
with step
•
If the input voltage is abnormal, proceed
with the next step.
•
If the connection is OK, troubleshoot
LEDs are lit on the controller on page 358
•
If there is a problem with the connection,
repair the connection and start over.
Check the connection from the
power inlet to the power unit.
7
•
If the LEDs are normal, proceed with step
.
•
If the LEDs are abnormal, proceed with
the next step.
Check the LEDs of the Ethernet
ports X3, X12 on the power unit.
8
•
If the connection is OK, proceed with
step
•
If there is a problem with the connection,
repair the connection and go to step
Check the connection of the Ether-
net cables.
9
Use a multimeter and insulating gloves.
Measure the AC OK signal.
10
The AC OK should be 0 V.
Make sure that connector X13 is connected
properly on both ends.
•
If the AC OK signal is 24 V, proceed with
step
•
If the AC OK signal is 0 V, proceed with
the next step.
If message numbers 34401/34402, proceed with
step
.
Check event log if there is a mes-
sage about DC-link voltage.
11
If not, power unit is ok.
How to replace the unit is detailed in
The power unit may be faulty, re-
place it and verify that the fault has
been fixed.
12
386
Product manual - OmniCore C90XT
3HAC073706-001 Revision: D
© Copyright 2020-2021 ABB. All rights reserved.
7 Troubleshooting
7.3.4 Troubleshooting the power unit
Continued
Содержание OmniCore C90XT
Страница 1: ...ROBOTICS Product manual OmniCore C90XT ...
Страница 2: ...Trace back information Workspace 21A version a14 Checked in 2021 03 30 Skribenta version 5 4 005 ...
Страница 50: ...This page is intentionally left blank ...
Страница 350: ...This page is intentionally left blank ...
Страница 354: ...This page is intentionally left blank ...
Страница 412: ...This page is intentionally left blank ...
Страница 444: ...This page is intentionally left blank ...
Страница 448: ......
Страница 449: ......