Significance
Description
Normal sequence during startup:
1
Red, solid: Default at power-up.
2
Red, flashing: Establish connection to main computer and load
program to axis computer.
3
Green, flashing: Start-up of axis computer program and connect
peripheral units.
4
Green, solid: Start-up sequence ready. Application is running.
The following indicates errors:
•
No color: No power to axis computer or internal error (hard-
ware/firmware).
•
Red, solid: The axis computer has failed to initialize basic hard-
ware.
•
Red, flashing continuously: Missing connection to main computer,
main computer start-up problem or RobotWare installation problem.
•
Green, flashing continuously: Missing connections to peripheral
units or RobotWare start-up problem.
Axis computer
status LED
Shows the status of Ethernet communication.
Ethernet LED
Green:
•
Off:10 Mbps data rate is selected.
•
On:100 Mbps data rate is selected.
Yellow:
•
Flashing: The two units are communicating on the Ethernet chan-
nel.
•
Solid: A LAN link is established.
•
Off: A LAN link is
not
established.
Product manual - OmniCore C90XT
397
3HAC073706-001 Revision: D
© Copyright 2020-2021 ABB. All rights reserved.
7 Troubleshooting
7.3.8 Troubleshooting the axis computer
Continued
Содержание OmniCore C90XT
Страница 1: ...ROBOTICS Product manual OmniCore C90XT ...
Страница 2: ...Trace back information Workspace 21A version a14 Checked in 2021 03 30 Skribenta version 5 4 005 ...
Страница 50: ...This page is intentionally left blank ...
Страница 350: ...This page is intentionally left blank ...
Страница 354: ...This page is intentionally left blank ...
Страница 412: ...This page is intentionally left blank ...
Страница 444: ...This page is intentionally left blank ...
Страница 448: ......
Страница 449: ......