![ABB OmniCore C90XT Скачать руководство пользователя страница 156](http://html.mh-extra.com/html/abb/omnicore-c90xt/omnicore-c90xt_product-manual_3132156.webp)
4.2 Inspection activities
4.2.1 Inspection of controller
Inspecting the OmniCore C90XT controller
Note/illustration
Action
DANGER
Before doing any work inside the cabinet,
disconnect the mains power. For more
information, see
1
Location of wrist strap button:
ELECTROSTATIC DISCHARGE
(ESD)
The unit is sensitive to ESD. Before
handling the unit read the safety inform-
ation in section
2
xx1900001446
Inspect connectors and cabling to make
sure they are securely fastened and
cabling not damaged.
3
Inspect the fans and ventilation holes to
make sure they are clean.
4
After inspection: Temporarily turn the
power supply on. Inspect the fans to
make sure they function correctly. Switch
the power off.