Specifications
It is recommended to use multicore cable for the customer connection.
The following describes the cable requirements for the X106 connection in the
extension box.
Description
Component
Flexible oil resistant rubber
Cable type
4C x 0.5 mm
2
or AWG20
Cable area
Included parts
The following parts are included in the delivery when the extension box is selected.
Quantity
Order number
Part
1
3HAC074661-001
Connector for X106
Procedure
Use this procedure to stack an extension box to a basic box.
Info/illustration
Action
Place the controller in desired place.
1
Anchor bolts: M8 X 4
Fix the basic box to a concrete foundation
or steel platform with anchor bolts.
2
Tighten torque: 11.3 Nm-12.6 Nm
xx1900001450
Remove the four plastic screw.
3
Continues on next page
146
Product manual - OmniCore C90XT
3HAC073706-001 Revision: D
© Copyright 2020-2021 ABB. All rights reserved.
3 Installation and commissioning
3.8.1 Installing the extension box
Continued