However, SafeMove may generate other warning messages anytime during the
Axis Calibration routine. When a warning message is displayed, tap
Acknowledge
to confirm the unsynchronized state and continue Axis Calibration procedure.
CAUTION
SafeMove must be synchronized after the calibration is completed.
After calibration
Note
Action
xx1600002102
Check the o-ring on the fixed calibration pin.
Replace if damaged or missing.
1
Reinstall the protective cover on the fixed calibra-
tion pin on each axis, directly after the axis has
been calibrated.
Replace the cover with new spare part, if missing
or damaged.
2
Protection cover and plug set:
3HAC056806-001.
xx1500000952
Reinstall the protective plug and sealing in the
bushing on each axis, directly after the axis has
been calibrated. Ensure that the sealing is not
damaged.
Replace the plug and the sealing with new spare
part, if missing or damaged.
3
Protection cover and plug set:
3HAC056806-001.
See
Calibrating with Wrist Optimiz-
If the standard calibration data for axes 4, 5 or 6
should be updated with wrist optimization, run the
calibration routine
Wrist Optimization
.
4
Product manual - IRB 6700Inv
693
3HAC058254-001 Revision: L
© Copyright 2017 - 2020 ABB. All rights reserved.
5 Calibration
5.4.4 Axis Calibration - Running the calibration procedure
Continued
Содержание IRB 6700I
Страница 1: ...ROBOTICS Product manual IRB 6700Inv ...
Страница 2: ...Trace back information Workspace 20D version a8 Checked in 2020 12 11 Skribenta version 5 3 075 ...
Страница 16: ...This page is intentionally left blank ...
Страница 40: ...This page is intentionally left blank ...
Страница 182: ...This page is intentionally left blank ...
Страница 672: ...This page is intentionally left blank ...
Страница 704: ...This page is intentionally left blank ...
Страница 720: ...This page is intentionally left blank ...
Страница 722: ...This page is intentionally left blank ...
Страница 729: ......