Note
Action
Cover insert: 3HAC048520-001.
xx1700001803
Fit the cover insert around the new cabling
and secure it with a weatherstrip.
12
Weatherstrip: 3HAC053986-001.
xx1700001804
xx1200000045
DressPack
or
Foundry Plus
:
Refit the cover with the tube guiding ring
fitted.
Note
Foundry Plus
:
•
Make sure the gasket is fitted cor-
rectly
•
Use attachment screws made of
stainless steel to fit the cover.
13
Continues on next page
252
Product manual - IRB 6700Inv
3HAC058254-001 Revision: L
© Copyright 2017 - 2020 ABB. All rights reserved.
4 Repair
4.4.2 Refitting the cable harness
Continued