Restoring the balancing device
Note
Action
Remove the lifting equipment from the balancing
device.
1
xx1700001406
Jog axis 2 to -4° to be able to remove the relief
screws.
2
xx1700000070
Remove the relief screws to activate the balancing
device.
Note
Axis 2 must be in -4°.
3
xx1700000451
Refit the covers. Make sure that the o-rings are
still fitted.
Note
Only manual force is required, no tightening
torque.
4
408
Product manual - IRB 6700Inv
3HAC058254-001 Revision: L
© Copyright 2017 - 2020 ABB. All rights reserved.
4 Repair
4.6.1 Replacing the spherical roller bearing
Continued