Note
Action
xx1300000544
Cut the cable tie at the cable fixing bracket.
Note
If DressPack is fitted, the cable fixing
bracket is replaced by the cable guide.
xx1300001973
Cable guide.
9
Cable fixing bracket.
xx1300000541
Remove the metal clamp on top of the arm
house.
10
Continues on next page
224
Product manual - IRB 6700Inv
3HAC058254-001 Revision: L
© Copyright 2017 - 2020 ABB. All rights reserved.
4 Repair
4.4.1 Removing the cable harness
Continued
Содержание IRB 6700I
Страница 1: ...ROBOTICS Product manual IRB 6700Inv ...
Страница 2: ...Trace back information Workspace 20D version a8 Checked in 2020 12 11 Skribenta version 5 3 075 ...
Страница 16: ...This page is intentionally left blank ...
Страница 40: ...This page is intentionally left blank ...
Страница 182: ...This page is intentionally left blank ...
Страница 672: ...This page is intentionally left blank ...
Страница 704: ...This page is intentionally left blank ...
Страница 720: ...This page is intentionally left blank ...
Страница 722: ...This page is intentionally left blank ...
Страница 729: ......