Note
Action
A
B
A
xx1000000367
Check that the
sealing ring
is in the correct
position. The
groove
for locking the cable
guide shall be visible as shown in the figure.
4
•
A: Sealing ring
•
B: Groove
xx1000000368
Adjust the
protection pipe
to the
correct
position
as shown in the figure by pushing
it up inside the
center tube
.
Note
The protection pipe is accessible from in-
side the base.
5
•
A: Groove
•
B: Correct position of protection
pipe
•
C: Protection pipe
•
D: Center tube
Continues on next page
402
Product manual - IRB 6640 Foundry Prime
3HAC040586-001 Revision: N
© Copyright 2011-2018 ABB. All rights reserved.
4 Repair
4.7.1 Replacing gearbox axis 1
Continued