Note
Action
xx1500000415
Carefully snap the I/O board loose (it is rail
mounted).
2
Removing the SMB connectors
Note
Action
DANGER
Make sure that all supplies for electrical power
and air pressure are turned off.
1
ELECTROSTATIC DISCHARGE (ESD)
The unit is sensitive to ESD. Before handling the
unit please read the safety information in the
section
WARNING - The unit is sensitive to ESD!
2
xx1500000416
Disconnect the connectors (left and/or right side):
•
A5X.SMB.X4
•
A5X.SMB.X5
•
A5X.SMB.X2
•
A52.SMB.X1
3
Removing the SMB board
Note
Action
DANGER
Make sure that all supplies for electrical power
and air pressure are turned off.
1
Disconnect the battery connector (X3)
2
xx1500000417
Remove two attachment screws.
3
Continues on next page
368
Product manual - IRB 14000
3HAC052983-001 Revision: D
© Copyright 2015 - 2016 ABB. All rights reserved.
4 Repair
4.7.11 Replacing the SMB boards
Continued
Содержание IRB 14000
Страница 1: ...Product manual IRB 14000 ...
Страница 2: ...Trace back information Workspace R16 2 version a5 Checked in 2016 09 08 Skribenta version 4 6 318 ...
Страница 8: ...This page is intentionally left blank ...
Страница 16: ...This page is intentionally left blank ...
Страница 416: ...This page is intentionally left blank ...
Страница 436: ...This page is intentionally left blank ...
Страница 440: ...This page is intentionally left blank ...
Страница 456: ......
Страница 457: ......