Note
Action
xx1500000308
Loosen the left attachment screw and remove the
right attachment screw.
4
Slide the power distribution board to the right.
5
Lift the power distribution board out.
6
Refitting the power distribution board
Use this procedure to refit the power distribution board.
Refitting the power distribution board
Note
Action
DSQC 662 Power distribution
board: 3HAC026254-001
Place the power distribution board and slide it to
the left.
1
Screws: M3x6 (2 pcs).
Tighten the left attachment screw and refit the
right attachment screw.
2
Tightening torque: 0.9 Nm.
xx1500000308
Connect the connectors:
•
G2.X8 (X8)
•
G2.XS2 (X2)
•
G2.XS1 (X1)
•
G2.XS3 (X3)
•
G2.XS6 (X6)
•
G2.XS5 (X5)
•
G2.XS7 (X7)
•
G2.XS4 (X4)
3
Put two cable ties around the plate and the G2.X8
connector.
4
Continues on next page
328
Product manual - IRB 14000
3HAC052983-001 Revision: D
© Copyright 2015 - 2016 ABB. All rights reserved.
4 Repair
4.7.5 Replacing the power distribution board
Continued
Содержание IRB 14000
Страница 1: ...Product manual IRB 14000 ...
Страница 2: ...Trace back information Workspace R16 2 version a5 Checked in 2016 09 08 Skribenta version 4 6 318 ...
Страница 8: ...This page is intentionally left blank ...
Страница 16: ...This page is intentionally left blank ...
Страница 416: ...This page is intentionally left blank ...
Страница 436: ...This page is intentionally left blank ...
Страница 440: ...This page is intentionally left blank ...
Страница 456: ......
Страница 457: ......