Removing the axis-2 mechanical stop
Note
Action
DANGER
Make sure that all supplies for electrical
power and air pressure are turned off.
1
xx1500000488
Remove the mechanical stop by removing
the two screws and washers.
2
Refitting the mechanical stop
Use these procedures to refit the mechanical stop.
Refitting the axis-2 mechanical stop
Note
Action
Mechanical stop for axis 2: 3HAC047602-
001
Refit the mechanical stop with the screws
and washers.
1
Screws: 3HAB3409-241 (2 pcs).
Tightening torque: 0.4 Nm.
xx1500000488
Continues on next page
Product manual - IRB 14000
285
3HAC052983-001 Revision: D
© Copyright 2015 - 2016 ABB. All rights reserved.
4 Repair
4.6.2 Replacing the axis-2 mechanical stop
Continued