Removing the arm
Use these procedures to remove the arm.
Preparations before removing the arm
Note
Action
Jog the robot so that the covers can be
easily accessed and removed.
1
DANGER
Turn off all:
•
electric power supply
•
air pressure supply
to the robot, before starting the repair work
on the robot.
2
Removing the body covers
Note
Action
DANGER
Make sure that all supplies for electrical
power and air pressure are turned off.
1
xx1400002904
Remove the body cover top screws.
2
Continues on next page
132
Product manual - IRB 14000
3HAC052983-001 Revision: D
© Copyright 2015 - 2016 ABB. All rights reserved.
4 Repair
4.3.1 Replacing the complete arm