![ABB IRB 14000 Скачать руководство пользователя страница 215](http://html.mh-extra.com/html/abb/irb-14000/irb-14000_product-manual_5024215.webp)
Note
Action
xx1500000541
Remove the inner part of the cooling flange.
7
Removing the axis-6 motor
Note
Action
DANGER
Make sure that all supplies for electrical
power and air pressure are turned off.
1
Disconnect the motor connectors.
2
Cut some cable ties, if needed.
•
R1.MP6R / R1.MP6L
•
R1.FB6R / R1.FB6L
CAUTION
Whenever parting/mating motor and gear-
box, the gears may be damaged if excess-
ive force is used!
3
xx1500000542
Remove the screws and lift the motor out
carefully.
4
Continues on next page
Product manual - IRB 14000
215
3HAC052983-001 Revision: D
© Copyright 2015 - 2016 ABB. All rights reserved.
4 Repair
4.4.7 Replacing the axis-6 motor