Removing the expansion board complete
Use this procedure to remove the expansion board complete.
Removing the fieldbus adapter
Note
Action
DANGER
Make sure that all supplies for electrical power
and air pressure are turned off.
1
ELECTROSTATIC DISCHARGE (ESD)
The unit is sensitive to ESD. Before handling the
unit please read the safety information in the
section
WARNING - The unit is sensitive to ESD!
2
(Depending on which connection is installed)
3
Disconnect the connector:
•
Profibus/S: A32.2
•
Ethernet/IP/S: A32.1
•
ProfiNet/S: A32.3
xx0700000193
A Attachment screw (2 pcs)
B Fastening mechanism
Loosen the attachment screws (2 pcs) on front of
the fieldbus adapter to release the fastening
mechanism.
Note
Do not remove the attachment screws, only loosen
them.
4
Continues on next page
Product manual - IRB 14000
383
3HAC052983-001 Revision: D
© Copyright 2015 - 2016 ABB. All rights reserved.
4 Repair
4.7.14 Replacing the expansion board complete
Continued