Note
Action
xx1500000601
Disconnect the grounding cable.
5
xx1500000365
Carefully pull the controller partially out in the
rails.
CAUTION
The cabling is still connected inside the robot, so
be careful not to strain the cables!
6
Removing the power distribution board
Note
Action
DANGER
Make sure that all supplies for electrical power
and air pressure are turned off.
1
Tip
Take a photography of the cable
placements to use at refit.
Cut cable tie at (X8).
2
Disconnect the connectors:
•
G2.X8 (X8)
•
G2.XS2 (X2)
•
G2.XS1 (X1)
•
G2.XS3 (X3)
•
G2.XS6 (X6)
•
G2.XS5 (X5)
•
G2.XS7 (X7)
•
G2.XS4 (X4)
3
Continues on next page
Product manual - IRB 14000
327
3HAC052983-001 Revision: D
© Copyright 2015 - 2016 ABB. All rights reserved.
4 Repair
4.7.5 Replacing the power distribution board
Continued