Note
Action
xx1400001142
Fit the R1.CP/CS cable to the customer plate.
10
xx1400001143
Secure the R1.CP/CS connector.
11
Screw, M6x20 8.8-A2F (2 pcs)
Tightening torque, brass couplings
1/2": 31 Nm
xx1200000088
Connect the hose connectors to the customer
plate.
CAUTION
Do not tighten the brass couplings for water and
air with excessive force.
CAUTION
Make sure that no cables or hoses are twisted or
strained. Reroute if necessary.
12
Connect the rest of the cable connectors to the
customer plate.
CAUTION
Make sure that no cables or hoses are twisted or
strained. Reroute if necessary.
13
Continues on next page
282
Product manual - DressPack/SpotPack IRB 6650S
3HAC055424-001 Revision: C
© Copyright 2004-2018 ABB. All rights reserved.
4 Repair
4.2.10 Replacing the cable package IRBDP SW6 LE LeanID
Continued