Removing the cable package - IRBDP SW6 LE
Note
Action
Move the robot to a comfortable working position.
1
DANGER
Turn off all:
•
electric power supply
•
air pressure supply
to the robot, before starting the repair work on the
robot.
2
CAUTION
The cable package is sensitive to mechanical
damage. Handle it with care in order to avoid
damaging the cabling or the connectors.
3
xx1400000197
Remove the rear top cover.
4
Disconnect connectors at the base.
5
From base to connection plate at
axis 3-4.
Open the straps holding the cable package.
6
xx1500000896
Unscrew the screws on the cable package bracket
from the axis-1 bracket.
7
Screw, M10x25 8.8-A3-F (2 pcs)
Carefully pull out the cable package from the base
in the following order:
•
Hoses
•
Weld cables
•
Remaining cables
8
Continues on next page
278
Product manual - DressPack/SpotPack IRB 6650S
3HAC055424-001 Revision: C
© Copyright 2004-2018 ABB. All rights reserved.
4 Repair
4.2.10 Replacing the cable package IRBDP SW6 LE LeanID
Continued
Содержание DressPack IRB6650S
Страница 1: ...ROBOTICS Product manual DressPack SpotPack IRB 6650S ...
Страница 2: ...Trace back information Workspace R18 1 version a11 Checked in 2018 03 25 Skribenta version 5 2 025 ...
Страница 8: ...This page is intentionally left blank ...
Страница 40: ...This page is intentionally left blank ...
Страница 206: ...This page is intentionally left blank ...
Страница 228: ...This page is intentionally left blank ...
Страница 346: ...This page is intentionally left blank ...
Страница 358: ...This page is intentionally left blank ...
Страница 384: ...This page is intentionally left blank ...
Страница 386: ...This page is intentionally left blank ...
Страница 388: ......
Страница 389: ......