Planning the electrical installation
58
3ADW000462R0401 DCS880 Hardware manual e d
Fan data for DCS880 (H5 ... H8)
The fan needs an input voltage of 400 V
AC
at 50 Hz. For 460 V
AC
/500 V
AC
use autotransformer
(T8).
The fan needs an input voltage of 460 V
AC
at 60 Hz. For 500 V
AC
use autotransformer (T8).
Fan connection for DCS880 (H5 ... H8)
Fan
R2E250-RB
GR28C-2DK
GR35C-2DD
Rated voltage [V
AC
]
230; 1~
400
500
460
400 / 460
/
500 V
460 /
500 V
Tolerance [%]
±10
±10
±10
±10
Frequency [Hz]
50
60
50
60
50
60
Power consumption [W]
227
390
660
600
1100
2100
3000
Current consumption [A]
1.1
1.7
1.4
0.8
1.8
4.0
5.3
Blocking current [A]
3.1
3.1
at 400 V
8.0
at 500 V 2.8
at 460 V
8.0 at 400 V > 17
at 460 V > 15
Air flow [m
3
/h]
at working point
800
1.0 A
850
1.6 A
1600 @ 1.2 A
(400 V
)
1500 @ 0.7 A
(500 V )
1700 @ 1.6 A
(460 V
)
4000 @ 4 A
(400 V)
4500 @ 5.3 A
(400 V)
Max. ambient temperature [°C]
< 55
< 55
Useful lifetime of grease
appr. 40,000 h/40°C
appr. 30,000 h/40°C
Protection
internal
Temperature detector: U
N
230 V~; I
N
2.5 A~
Converter housing
Configuration 5
H5, H6
Configuration 6
H7
Configuration 7
H8
U1
V1
W1
U2 V2 W2
TK TK
PE
at
U1-W2
V1-U2
W1-V2
M
~
J
U1
V1
W1
U2
V2
W2
PE TB TB
at
M
~
U1
V1
W1
U2
V2
W2
PE TB TB
at
U2 - V2 - W2
M
~
U1-W2
V1-U2
W1-V2
M
~
2
3
1
X2:
4
5
L
N
SA_880_011_DCS_FAN_b.ai
Connection
Connection
Connection