Accessories
138
3ADW000462R0401 DCS880 Hardware manual e d
DCF803-0050, DCF804-0050, DCF803-0060 and DCF804-0060
DCF803-0050 / 0060 and DCF804-0050 / 0060 are external single-phase field converters.
The
half controlled
(1-Q) field exciters DCF803-0050 / DCF803-0060 include the SDCS-FEX-82,
two thyristor/diode power modules and auxiliaries (power supply, line reactor L1).
The
full controlled
(4-Q) field exciters DCF804-0050 / DCF804-0060 include the SDCS-FEX-81,
four anti-parallel thyristor power modules and auxiliaries (power supply, line reactor L1).
The control structure is similar to the SDCS-FEX-4 in single-phase operation. A micro controller is
used for controlling the field current and firing. The DC current is measured using an AC current
transformer.
Cross section DCF803-0050, DCF803-0060, DCF804-0050, DCF804-0060:
Terminal
Flex cable
Max [mm²]
Torque [Nm]
X2
X3
0.25 … 1.5
0.5 … 0.6
X:U1
X:V1
X:C1
X:D1
10
10
M6
PE
10
10
M6
+
-
+
-
DCF
8
04-0050 / 0060
DCF
8
0
3
-0050 / 0060
SS_DCF_001_part_b.ai
L1
L1
T1500
T1500
Mains
Mains
Field
Field
C1 (+)
D1 (-)
U1
1
5
X6
V11, V12
V21, V22
V23, V24
V13, V14
X111 X112
X113 X114
X121 X122
X123 X124
T1
X71
1
SDCS-FEX-8x
X12
X11
V1
274
319
S2
1
3
4
2
1
X2
V731
1 2
X3
3
T1500
X8
BL_FETab_a.ai
L1
S1100
V730
S800
S801
X2:1
X2:2
X2:3
X2:4
X2:5
S1100:1
S1100:2
S1100:3
S1100:4
S1100:5
S1100:6
S1100:7
S1100:8
S801
S800
V730
V731
1
1
X5
1
X10
R902
R903
Line
reactor
Conductive supports
Isolating supports
Line
potential !
Reserved
Reserved
GNDB
CANL
CANH
Termination
Grounding
Grounding
Baudrate
Baudrate
Baudrate
Bridge reversal
Oper. mode
Node x10
Node 1 ... 9
Green
Yellow
Ground of communcation interface
DCSLink e.g. X52:2 or X53:2
DCSLink e.g. X52:3 or X53:3
ON = 120 Ohm bus termination
ON = GNDB to ground via 200 kOhm
ON = GNDB to ground, hard.
Default = OFF (500 kBd)
Default = OFF (500 kBd)
Default = ON (500 kBd)
ON = extended bridge reversal (+20 ms)
OFF = reserved; ON = DCS800
DCSLink node address digit 10
DCSLink node address digit 0
Fault and warning display, see chapter Diagnosis
Fault and warning display, see chapter Diagnosis