Technical data
100
3ADW000462R0401 DCS880 Hardware manual e d
Technical data
Auxiliary supply voltage XAUX (X99)
Input circuit XAUX (X99)
Features a hardware filter
and a voltage limitation
.
Armature circuit interface
The function for the armature circuit interface consist of:
– Firing the armature bridge of 6 or 12 thyristors.
– High ohmic measurement of DC and AC voltages.
– Residual current measurement of armature circuit to ground
= 5 mA at 500 V supply (
1 M
).
– Interface for the current transformers for current measurement.
– Snubber circuit for the thyristor protection together with R1 on the heatsink.
– Interface for heatsink temperature measurement with a PTC.
– Fuses for overvoltage protection and field circuit.
Auxiliary
voltage
115 V
AC
230 V
AC
230 V
DC
Tolerance
-15 % / +10 %
-15 % / +10 %
-15 % / +10 %
Frequency
45 Hz ... 65 Hz
45 Hz ... 65 Hz
-
Power consumption
120 VA
120 VA
-
Power loss
60 W
60 W
60 W
Inrush current
20 A / 20 ms
10 A / 20 ms
10 A / 20 ms
Recommended fusing
6 AT
6 AT
6 AT
Mains buffering
min. 30 ms
min. 300 ms
min. 150 ms
Powerfail
< 95 V
AC
< 95 V
AC
< 140 V
DC
SF_PINF_001_in-output_c.ai
5 AT
1
2
NTC
-
U
XAUX (X99):