Note
Action
xx2100000158
Release the holding brake of all axes by pressing
the brake release button.
The brake will be enable as soon as the button is
released.
WARNING
Pressing the brake release button will release the
holding brakes on all axes simultaneously.
3
Supplying power to connector R1.MP
If the robot is not connected to the controller, power must be supplied to connector
R1.MP on the robot, in order to enable the brake release buttons.
Note
Action
DANGER
Incorrect connections, such as supplying power
to the wrong pin, may cause all brakes to be
released simultaneously and instantly!
1
xx1800002443
Supply
•
0V on pin 12.
•
24V on pin 11.
Note
Do not interchange the 24V and 0V pins.
If they are mixed up, damage can be caused to
internal electrical components.
2
Use the brake releasing button as described in
Releasing the brakes on page 58
.
3
Product manual - CRB 1100
59
3HAC078007-001 Revision: J
© Copyright 2021-2023 ABB. All rights reserved.
3 Installation and commissioning
3.3.3 Manually releasing the brakes
Continued
Содержание CRB 1100
Страница 1: ...ROBOTICS Product manual CRB 1100 ...
Страница 2: ...Trace back information Workspace 23B version a17 Checked in 2023 06 29 Skribenta version 5 5 019 ...
Страница 162: ...This page is intentionally left blank ...
Страница 184: ...This page is intentionally left blank ...
Страница 652: ...This page is intentionally left blank ...
Страница 698: ...This page is intentionally left blank ...
Страница 712: ...This page is intentionally left blank ...
Страница 714: ...This page is intentionally left blank ...
Страница 719: ......