Reconnecting the axis-4 motor connectors
Note
Action
xx1800003618
Check the cabling status.
Make sure the cabling is in vertical state and is
not twisted.
1
xx1800003012
Reconnect the connectors.
•
FB4
•
MP4
Tip
See the number markings on the connectors for
help to find the corresponding connector.
2
Refitting the housing cover
Note
Action
Apply grease to the cable package, cover all
moving area of the package.
1
Apply grease to the covers that have contacting
area with the cable package.
2
Continues on next page
522
Product manual - CRB 1100
3HAC078007-001 Revision: J
© Copyright 2021-2023 ABB. All rights reserved.
5 Repair
5.7.4 Replacing the axis-4 motor
Continued