Disconnecting the air hoses, CP/CS cabling and Ethernet cabling (if equipped)
Note
Action
DANGER
Make sure that all supplies for electrical power,
hydraulic pressure, and air pressure are turned
off.
1
xx1800002500
Disconnect the air hoses from the Y-shaped con-
nectors.
2
xx1800002501
Disconnect the connectors.
•
J2.C1
•
J2.C2
Tip
Take photos of the connector and cable position
before disconnecting them, to have as a reference
when reconnecting.
Tip
The connector clip has to be pressed (1) and
pushed forward (2) to separate the J2.C2 (for
Ethernet cabling).
xx1800002943
3
Continues on next page
326
Product manual - CRB 1100
3HAC078007-001 Revision: J
© Copyright 2021-2023 ABB. All rights reserved.
5 Repair
5.4.2 Replacing the swing
Continued