Note
Action
xx1800002471
Remove the screws.
3
Refitting the SMB unit
Use these procedures to refit the SMB unit.
Refitting the SMB unit
Note
Action
ELECTROSTATIC DISCHARGE (ESD)
The unit is sensitive to ESD. Before handling the
unit read the safety information in section
unit is sensitive to ESD on page 48
1
Screw: M3x5 12.9 Lafre
2C2B/FC6.9 (4 pcs)
Refit the screws.
2
Tightening torque: 0.8 Nm
xx1800002471
Refitting the battery pack
Note
Action
ELECTROSTATIC DISCHARGE (ESD)
The unit is sensitive to ESD. Before handling the
unit read the safety information in section
unit is sensitive to ESD on page 48
1
Continues on next page
274
Product manual - CRB 1100
3HAC078007-001 Revision: J
© Copyright 2021-2023 ABB. All rights reserved.
5 Repair
5.3.3 Replacing the SMB unit
Continued