Configuring button functions
Note
The procedure is valid only for two-button type lead-through device.
The button-type lead-through device provides two buttons, flat and raised, for users
to configure specific functions according to application requirements. The button
function configuration is only available to robots:
•
operating in RobotWare version 7.6.1 or later, and,
•
installing with the Collaborative Speed Control add-in in version 1.1 or later
Use the following procedure to configure the button functions:
1 Tap
Settings
on the home page of the FlexPendant.
2 Tap
Lead-through Device
.
3 Tap
Configurable buttons
on the left pane.
4 Select desired function from the drop-down list for the required button.
•
Add a move location
: a
Move
block will be added to Wizard app. This
is the default configuration for the flat button.
•
Linear / Reorient
: the lead-through mode will be changed between
linear and reorient. This is the default configuration for the raised button.
•
Lock Z
: the movement along the Z direction will be locked.
•
Lock XY
: the movement along the X and Y directions will be locked.
After selection, configured action takes effect when pressing the button.
Product manual - CRB 1100
103
3HAC078007-001 Revision: J
© Copyright 2021-2023 ABB. All rights reserved.
3 Installation and commissioning
3.7.3 Lead-through
Continued
Содержание CRB 1100
Страница 1: ...ROBOTICS Product manual CRB 1100 ...
Страница 2: ...Trace back information Workspace 23B version a17 Checked in 2023 06 29 Skribenta version 5 5 019 ...
Страница 162: ...This page is intentionally left blank ...
Страница 184: ...This page is intentionally left blank ...
Страница 652: ...This page is intentionally left blank ...
Страница 698: ...This page is intentionally left blank ...
Страница 712: ...This page is intentionally left blank ...
Страница 714: ...This page is intentionally left blank ...
Страница 719: ......