Note
Action
xx1900000007
Remove the adjustment screw from the motor.
10
Reconnecting the axis-6 motor connectors
Note
Action
xx1800002994
Reconnect the connectors.
•
FB6
•
MP6
Tip
See the number markings on the connectors for
help to find the corresponding connector.
1
Route and secure the cabling with cable straps.
CAUTION
Correct cable routing is highly important.
If the cables are routed and secured incorrectly
the cables can be damaged.
2
Insert the cabling and connectors into the wrist.
3
Refitting the wrist covers
Note
Action
Apply grease to the cable package, cover all
moving area of the package.
1
Apply grease to the covers that have contacting
area with the cable package.
2
Continues on next page
Product manual - CRB 1100
543
3HAC078007-001 Revision: J
© Copyright 2021-2023 ABB. All rights reserved.
5 Repair
5.7.6 Replacing the axis-6 motor
Continued