![ABB ACS550 Series Скачать руководство пользователя страница 258](http://html.mh-extra.com/html/abb/acs550-series/acs550-series_user-manual_334258.webp)
258
ACS550 User’s Manual
Maintenance
Capacitors
Reforming
The drive DC link capacitors need to be reformed (re-aged) if the drive has been
non-operational for more than one year. Without reforming, capacitors may be
damaged when the drive starts to operate. It is therefore recommended to reform the
capacitors once a year. See section
on page
date of manufacture from the serial number shown on the drive labels.
For information on reforming the capacitors, refer to
Guide for Capacitor Reforming
in ACS50/150/350/550
[3AFE68735190 (English)], available on the Internet (go to
and enter the code in the Search field)
.
Replacement
The drive intermediate circuit employs several electrolytic capacitors. Their life span
is from 35 000
…
90 000 hours depending on drive loading and ambient temperature.
Capacitor life can be prolonged by lowering the ambient temperature.
It is not possible to predict a capacitor failure. Capacitor failure is usually followed by
a input power fuse failure or a fault trip. Contact ABB if capacitor failure is suspected.
Replacements for frame size R5 and R6 are available from ABB. Do not use other
than ABB specified spare parts.
Control panel
Cleaning
Use a soft damp cloth to clean the control panel. Avoid harsh cleaners which could
scratch the display window.
Battery
A battery is only used in Assistant Control Panels that have the clock function
available and enabled. The battery keeps the clock operating in memory during
power interruptions.
The expected life for the battery is greater than ten years. To remove the battery, use
a coin to rotate the battery holder on the back of the control panel. Replace the
battery with type CR2032.
Note:
The battery is NOT required for any control panel or drive function, except the
clock.
Содержание ACS550 Series
Страница 1: ...ACS550 User s Manual ACS550 01 Drives 0 75 132 kW ACS550 U1 Drives 1 200 hp ...
Страница 4: ......
Страница 10: ...10 ACS550 User s Manual Table of contents ...
Страница 84: ...84 ACS550 User s Manual Application macros ...
Страница 188: ...188 ACS550 User s Manual Parameters ...
Страница 242: ...242 ACS550 User s Manual Fieldbus adapter ...
Страница 276: ...276 ACS550 User s Manual Technical data WARNING Do not use RFI EMC filters on IT systems ...
Страница 296: ...296 ACS550 User s Manual Technical data ...