Regulator knob has continuous air leak
Damaged regulator.
Replace
Regulator will not shut off air outlet
Damaged regulator.
Replace
Overheating
1.Inlet and outlet filters
need cleaning / replacing
1.Check inlet and outlet filters. Clean and/or
replace as needed
2.Unusually dusty
environment
2.Clean and/or replace filters more often or move
unit to cleaner environment
3.Extension cord used
3.Eliminate extension cord.Instead of using an
extension cord by attaching another length of hose
to its end.
4.Unit not on level surface 4.Reposition unit on a level surface
5.Cord is too small of a
gauge or too long to
handle compressor
5.Increase cord size or use shorter length
extension cord, or eliminate extension cord. See
Recommended Wire Gauge for Extension Cords
6.Dirty compressor, head,
cylinder, intercooler
6.Clean with compressed air
7.Operating pressure too
high
7.Reduce operating pressure
8.Compressor cycle too
long. it is recommended
that a 50%-75% average
duty cycle be maintained
8.Allow for longer rest between cycles,
See “duty cycle” in “glossary” section.
9.Valve is faulty
9.Contact a trained service technician.
10.Insufficient air flow to
cool Unit,Blocked air
circulation at the Unit
10.Check the air circulation in and around the
Unit,contact a trained service technician.
11.Ambient temperature
too high
11.contact a trained service technician
12.Faulty Temperature
Switch
12.contact a trained service technician
Excessive Vibration
1.Loose compressor, motor
components
1.Tighten components
2.Excessive discharge
pressure
2.Reduce operating pressure