background image

OWNER’S OPERATING MANUAL

DIRECT DRIVE COMPRESSOR

MODEL RC-1524D

KEEP THIS MANUAL FOR FUTURE REFERENCE

Your new compressor has been engineered and manufactured to Ryobi’s high

standard of dependability, ease of operation and operator safety. Properly cared

for, it will give you years of rugged, trouble free performance. If you use your

compressor properly and only for what it is intended, you will enjoy years of

safe, reliable service.

SPECIFICATIONS

Voltage...................................................................................................230V~50Hz

Rated power........................................................................................ 1.1kW/1.5HP

Receiver capacity................................................................................................ 24l

Type..................................................................................................... Oil lubricated

Free air delivery (FAD)............................................................................... 150l/min

Oil type......................................................................................................... SAE-30

Oil capacity......................................................................................................270ml
Working pressure................................................................................... 8bar/116psi

No load speed...........................................................................................2850min

-1

Sound pressure level..........................................................L

pA

73.9dB(A),k=3dB(A)

Sound power level............................................................. L

WA

93.9dB(A),k=3dB(A)

Net weight......................................................................................................... 22kg

THANK YOU FOR BUYING A RYOBI

DIRECT DRIVE COMPRESSOR

CAUTION: Carefully read through this entire owner’s

manual, paying close attention to the general

safety rules and rules for safe operation,

before using.

1

Содержание RC-1524D

Страница 1: ... intended you will enjoy years of safe reliable service SPECIFICATIONS Voltage 230V 50Hz Rated power 1 1kW 1 5HP Receiver capacity 24l Type Oil lubricated Free air delivery FAD 150l min Oil type SAE 30 Oil capacity 270ml Working pressure 8bar 116psi No load speed 2850min 1 Sound pressure level LpA 73 9dB A k 3dB A Sound power level LWA 93 9dB A k 3dB A Net weight 22kg THANK YOU FOR BUYING A RYOBI ...

Страница 2: ... The warnings and safety instructions must be followed to ensure reasonable safety and efficiency in using this product NOTE The operator is responsible for following the warnings and safety instructions in this manual and on the product Ensure that this compressor is disconnected from the mains supply when not in use and the air receiver fully discharged before servicing lubricating or making adj...

Страница 3: ...afe Never weld or drill holes in the air tanks Only use recommended parts To avoid the risk of bursting only hoses with a rated pressure of 8 bar or more should be used Never attempt to repair faulty hoses Avoid kinking or trapping the air hose Always replace faulty hoses never attempt a repair if a leak is detected Make sure the hose is free of obstructions or snags Entangled or snarled hoses can...

Страница 4: ... with ANSI Z87 1 c Additional safety protection will be required in some environments For example the working area may include exposure to a noise level which can lead to hearing damage The employer and user must ensure that any necessary hearing protection is provided and used by the operator and others in the work area Some environments will require the use of head protection equipment When requ...

Страница 5: ...ct is powered by a precision built electric motor It should be connected to a power supply that is 230 V AC only normal household current 50 Hz Do not operate this product on direct current DC A substantial voltage drop will cause a loss of power and the motor will overheat If the product does not operate when plugged into an outlet double check the power supply GROUNDING INSTRUCTIONS This product...

Страница 6: ...4 Air outlet pressure regulator lock ring 5 Air outlet quick release connector regulated 6 Air outlet pressure gauge 7 Air receiver pressure gauge 8 Rubber foot 9 Drain valve 10 Wheel x 2 11 Air receiver tank 12 Air pump motor 13 Oil fill cap DESCRIPTION 11 1 2 8 9 10 3 6 7 4 5 13 12 ...

Страница 7: ...7 14 Air intake filter 15 Oil fill sight glass 16 Safety valve DESCRIPTION 14 15 16 ...

Страница 8: ...t flat washer spring washer nut x 2 Rubber foot Rubber foot fixings bolt nut Air intake filter Oil fill cap Operator s Manual WARNING If any parts are damaged or missing do not operate this product until the parts are replaced Use of this product with damaged or missing parts could result in serious personal injury WARNING Do not connect to power supply until assembly is complete Failure to comply...

Страница 9: ...carbon deposits on pump components thus reducing performance and compressor life WARNING Drain the tank to release all tank air pressure before removing the oil fill cap Be sure the air vent in the oil fill cap Fig 4 is free from debris If air vent is blocked pressure can build in crankcase causing damage to the compressor and possible personal injury Remove the oil fill cap by twisting it upwards...

Страница 10: ...ng used play an important role in the operation of this product Wiring intended for lights cannot properly carry an air compressor motor and wire that is heavy enough for a short distance may be insufficient for a greater distance Before using this product verify your receptacle is wired appropriately for air compressor use and the length and gauge of any extension cord used is sufficient to carry...

Страница 11: ...that the drain valve is closed Fig 8 Connect the compressor to a suitable 16A mains supply Switch on the compressor by pulling up the On Off switch Fig 9 The compressor will now start When the air receiver tank is pressurised to its working capacity the compressor will automatically switch off When the compressor switches off there will be the sound of leaking air while the pressure regulating sys...

Страница 12: ...at the same time observing the air outlet pressure gauge until the pressure gauge reads the minimum pressure for the accessory Fine adjustments to the air pressure can be made until the accessory is working at its optimum performance When the correct operating air pressure has been set the air outlet pressure regulator can be locked by tightening the locking ring Fig 12 Do not exceed the maximum r...

Страница 13: ...le container beneath the compressor to catch any condensation Carefully undo the drain valve nut anti clockwise until you hear a hissing noise this is the reservoir depressurising Fig 15 When the gauge indicates zero and the hissing has stopped tighten the drain valve nut again OIL CHANGING For changing the pump oil be sure to do the following 1 Turn the unit off and unplug the power cord from the...

Страница 14: ...ning and maintaining the compressor regularly will give a long and trouble free life Before long term storage it is advisable to give the compressor a thorough clean This should include the removal of all fitted accessories Do not use any solvents as these can damage plastic parts Only use a clean cloth dampened with warm soapy water Any metal parts should be given a wipe with a light machine oil ...

Страница 15: ...failure Pressure switch fault Filter clogged Head gasket or valve fault Low oil level Bearing or piston damage Check unit is plugged in Check fuse breaker Replace blown fuse Reset determine cause of problem Take compressor to service center Clean the air ducts Ventilate the work area Check the compressed air hose and tools and replace if necessary Check the quick release connector and replace if n...

Страница 16: ... power source before servicing Do not use in damp conditions Hot Surface To reduce the risk of injury or damage avoid contact with any hot surface Enclosure Alert Do not operate the portable compressor with the doors or enclosure open Unexpected Starting The compressor may start without warning Recycle Symbol Waste electrical products should not be disposed of with household waste Please recycle w...

Страница 17: ...erious injury WARNING Indicates a potentially hazardous situation which if not avoided could result in death or serious injury CAUTION Indicates a potentially hazardous situation which if not avoided may result in minor or moderate injury CAUTION Without Safety Alert Symbol Indicates a situation that may result in property damage ...

Страница 18: ...18 NOTES ...

Страница 19: ...19 NOTES ...

Страница 20: ......

Отзывы: