11
DUTY CYCLE:
This air compressor
pump is capable of running
continuously. However, to prolong
the life of your air compressor, it is
recommended that a 50%-75%
average duty cycle be maintained;
that is, the air compressor pump
should not run more than 30-45
minutes in any given hour.
SPECIFICATIONS
Electrical Rating 120V
〜
/ 60Hz /
2.5Amp
Air Outlet Size 1/4”-18NPT
Air
Pressure
Shut-off 100 PSI
Restart 85 PSI
Air Tank Capacity 3 Gallons
Air Flow Capacity 0.6 SCFM @ 90 PSI
1 SCFM @ 40 PSI
KNOW YOUR AIR
COMPRESSOR
READ THIS OWNER’S MANUAL AND
SAFETY RULES BEFORE OPERATING
YOUR UNIT
. Compare the illustrations
with your unit to familiarize yourself
with the location of various controls
and adjustments. Save this manual for
future reference.
1. Power
Switch
2. Reset Button
3 Tank Air Pressure Gauge
4. Safety Valve
5. Regulator Knob
6. Air Outlet
7. Output Air Pressure Gauge
The diagrams and pictograms
herewith enclosed in this manual are
are a guide but not necessarily an
exact copy of the actual product.
Become familiar with these controls
before operating the unit.
On(I)/Off(O) Power Switch:
Place
this switch in the On (I) position to
provide automatic power to the
pressure switch and Off (O) to remove
power at the end of each use.
Pressure Switch (not shown):
The
pressure switch automatically starts
the motor when the air tank pressure