background image

 

 

14

   

125 V~ 3-Prong Plug and Outlet (for 

up to 125 V~ and up to 15 A) 

2.

 

Make sure the outlet being used 

has the same configuration as the 

grounded plug.

 DO NOT USE AN 

ADAPTER

3.

 

Inspect the plug and cord before 

each use. Do not use if there are 

signs of damage. 

4.

 

Check with a qualified electrician, 

if you are in doubt as to whether 

the outlet is properly grounded. Do 

not modify the power cord plug 

provided with the compressor.

 

5.

 

Never remove the grounding 

prong from the plug. Do not use the 

compressor if the power cord or plug 

is damaged. If damaged, have it 

repaired by a service facility before 

use. 

If the plug will not fit the outlet, 

have a proper outlet installed by a 

qualified electrician

6.

 

In the event of a malfunction or 

breakdown, grounding provides a 

path of least resistance for electric 

current to reduce the risk of electric 

shock. This compressor is equipped 

with an electric cord having an 

equipment-grounding conductor and 

a grounding plug. The plug must be 

plugged into a matching outlet that 

is properly installed and grounded in 

accordance with all local codes and 

ordinances.Do not modify the plug 

provided -if it will not fit the outlet, 

have the proper outlet installed by a 

qualified electrician. 

7.

 

Improper connection of the 

equipment-grounding conductor can 

result in a risk of electric shock. 

8.

 

The conductor with insulation 

having an outer surface that is green 

with or without yellow stripes is the 

equipment-grounding conductor.If 

repair or replacement of the electric 

cord or plug is necessary, do not 

connect the equipment- grounding 

conductor to a live terminal. 

9.

 

Repair or replace damaged or 

worn cord immediately. 

 

Repairs to the cord set or plug MUST 

be made by a qualified electrician. 

 

Break-in the Compressor 

   

Break in the new Air Compressor as 

follows: 

a)

 

Turn the Power Switch

 OFF

 and 

unplug the unit. Insert a male coupler 

(not provided)into the female Quick 

Coupler and fully open all regulators 

and valves. 

b)

 

Plug in the Power Cord. 

c)

 

Turn the Power Switch 

ON

d)

 

Let the unit run for

 30 

minutes. 

Air will expel freely through the 

Coupler. 

e)

 

Turn the Power Switch 

OFF

Unplug the Power Cord and remove 

the male coupler. 

 

 

Air Connection Setup 

1. Connect a regulator valve, an inline 

shut off valve and a 1/4" NPT air hose 

to the Quick Coupler (all not 

provided ). The air hose must be long 

enough to reach the work area with 

enough extra length to allow free 

Содержание A12101

Страница 1: ...l before assembling operating and maintaining this unit You are responsible for operating the product properly safely Version V1 20171222 A A V I X O U T D O O R S FOR SERVICE CALL USA 1 866 591 8921...

Страница 2: ...l cannot cover all possible conditions and situations that may occur It must be understood by the operator that common sense and caution are factors which cannot be built into this product but must be...

Страница 3: ...pressor use and care a Do not use the compressor if the power Switch does not turn it on and off Any compressor that cannot be controlled with the power Switch is dangerous and must be repaired b Disc...

Страница 4: ...hever is greater 10 Industrial applications must follow OSHA guidelines 11 Maintain labels and nameplates on the compressor These carry important safety information If unreadable or missing contact ou...

Страница 5: ...w the compressor to operate unattended HOW TO PREVENT IT Always remain in attendance with the product when it is operating Always turn off and unplug unit when not in use Do not leave compressor unatt...

Страница 6: ...k of injury to consumers Your compressor air tank must be removed from service by the end of the year shown on your tank warning label The following conditions could lead to a weakening of the air tan...

Страница 7: ...TO PREVENT IT Never operate the compressor outdoors when it is raining or in wet conditions Never operate compressor with protective covers removed or damaged 2 WHAT CAN HAPPEN Repairs attempted by un...

Страница 8: ...parts such as the pulley flywheel and belt can cause serious injury if they come into contact with you or your clothing HOW TO PREVENT IT Never operate the compressor with guards or covers which are d...

Страница 9: ...der some conditions and duration of use noise from this product may contribute to hearing loss HOW TO PREVENT IT Always wear proper hearing protection during use 27 AIR RECEIVER Over pressurizing the...

Страница 10: ...esulting in power loss to the motor and overheating Instead of using an extension cord increase the working reach of the air hose by attaching another length of hose to its end Attach additional lengt...

Страница 11: ...YOUR UNIT Compare the illustrations with your unit to familiarize yourself with the location of various controls and adjustments Save this manual for future reference 1 Power Switch 2 Reset Button 3...

Страница 12: ...for this fan to blow air through the vent holes in large amounts You know that the cooling system is working when air is being expelled Air Compressor Pump not shown Compresses air into the air tank...

Страница 13: ...cated at least 12 30 5 cm away from the wall or other obstructions that will interfere with the flow of air The air compressor pump and shroud are designed to allow for proper cooling The ventilation...

Страница 14: ...ces Do not modify the plug provided if it will not fit the outlet have the proper outlet installed by a qualified electrician 7 Improper connection of the equipment grounding conductor can result in a...

Страница 15: ...ilter or a dryer all not provided as shown on Figure A and Figure B Consult your air tool s manual for needed accessories A Portable Air Supply Setup A Air Hose Connects air to tool B Filter Prevents...

Страница 16: ...of use H Air Hose Connects air to tool I Filter Prevents dirt and condensation from damaging tool or workpiece J Regulator Adjusts air pressure to tool K Lubricator optional For air tool lubrication L...

Страница 17: ...ies The regulator outlet pressure must never exceed the maximum pressure rating NOTE Risk of property damage Compressed air from the unit may contain water condensation and oil mist Do not spray unfil...

Страница 18: ...pressure switch The Compressor will turn on automatically when the air pressure drops to 85 PSI and will turn off automatically when the air pressure reaches 100 PSI WARNING TO PREVENT SERIOUS INJURY...

Страница 19: ...otor Overload Protector Automatic Shut Off System not shown The motor has a thermal overload protector If the motor overheats for any reason the overload protector will shut off the motor The motor mu...

Страница 20: ...mpressor NOTE The environment in which the compressor is used and the frequency of use can affect how often you will need to check the Air Compressor components and perform maintenance procedures DAIL...

Страница 21: ...Operation Air tanks contain high pressure air Keep face and other body parts away from outlet of drain Use ANSI Z87 1 eye protection CAN CSA Z94 3 when draining as debris can be kicked up into face W...

Страница 22: ...arts Personal injuries can occur Before performing any maintenance or repair disconnect power source from the compressor and bleed off all air pressure and allow the air compressor to cool 1 Release a...

Страница 23: ...ee To Drain Tank under Maintenance WARNING Water will condense in the air tank If not drained water will corrode and weaken the air tank causing a risk of air tank rupture 3 Protect the electrical cor...

Страница 24: ...urely Disconnect the other electrical appliances from circuit or operate the compressor on its own branch circuit Check the extension cord Check wiring connection inside terminal box 3 Incorrect power...

Страница 25: ...t start up again on its own See Motor Overload Protector in OPERATION section contact a trained service technician 5 Loose fittings 5 Reduce air pressure then check all fittings with a soap solution f...

Страница 26: ...lace with wider hose and or hose connections 9 High altitude reducing air output 9 Higher altitudes require compressors with greater output 10 Pressure switch adjusted too low or 10 Make necessary adj...

Страница 27: ...ion cord or eliminate extension cord See Recommended Wire Gauge for Extension Cords 6 Dirty compressor head cylinder intercooler 6 Clean with compressed air 7 Operating pressure too high 7 Reduce oper...

Страница 28: ...Excessive tank pressure safety valve pops off 1 Safety valve needs service 1 Pull on test ring of safety valve If it still pops replace 2 Pressure switch does not shut off motor when compressor reache...

Страница 29: ...01 44 13 Plain Washer 1 A12101 13 45 Bolt 4 A12101 45 14 Fan 1 A12101 14 46 Bolt 3 A12101 46 15 Screw 2 A12101 15 47 Plain Washer 3 A12101 47 16 Ground Wire 1 A12101 16 48 Pressure Switch 1 A12101 48...

Страница 30: ...30 EXPLODED VIEW...

Отзывы: