12

   

drops below the factory set "cut-in" 

pressure. It stops the motor when the 

air tank pressure reaches the factory 

set "cut-out" pressure. 

Safety Valve : 

If the pressure switch 

does not shut off the air compressor at 

its "cutout" pressure setting, the safety 

valve will protect against high pressure 

by "popping out" at its factory set 

pressure (slightly higher than the 

pressure switch "cut-out" setting).   

Tank Pressure Gauge: 

The tank 

pressure gauge indicates the reserve 

air pressure in the tank. 

Outlet Pressure Gauge:

 The outlet 

pressure gauge indicates the air 

pressure available at the outlet side 

of the regulator. This pressure is 

controlled by the regulator and is 

always less than or equal to the tank 

pressure. 

Regulator Knob: 

Controls the air 

pressure shown on the outlet 

pressure gauge. Turn regulator knob 

clockwise to increase pressure and 

counterclockwise to decrease 

pressure.   

Cooling System (not shown): 

This 

compressor contains an advanced 

design cooling system. At the heart of 

this cooling system is an engineered 

fan. It is perfectly normal for this fan 

to blow air through the vent holes in 

large amounts. You know that the 

cooling system is working when air is 

being expelled. 

Air Compressor Pump (not 
shown): 

Compresses air into the air 

tank. Working air is not available until 

the compressor has raised the air 

tank pressure above that required at 

the air outlet. 

Drain Valve : 

The drain valve is 

located at the base of the air tank and 

is used to drain condensation at the 

end of each use. 

Check Valve: 

When the air 

compressor is operating, the check 

valve is "open", allowing compressed 

air to enter the air tank. When the air 

compressor reaches "cut-out" 

pressure, the check valve "closes", 

allowing air pressure to remain inside 

the air tank. 

 

INSTALLATION 

UNPACKING

 

When unpacking, make sure that the 

product is intact and undamaged. If 

any parts are missing or broken, 

please call our customer service center 

as soon as possible. 

 

WARNING:

 

Read the ENTIRE IMPORTANT SAFETY 

INFORMATION section at the 

beginning of this manual including all 

text under subheadings therein 

before set up or use of this product. 

 

TO PREVENT SERIOUS INJURY FROM 

ACCIDENTAL OPERATION: 

Turn the Power Switch “OFF” and 

unplug the Air compressor from its 

electrical outlet before assembling or 

making any adjustments to the 

Содержание A12101

Страница 1: ...l before assembling operating and maintaining this unit You are responsible for operating the product properly safely Version V1 20171222 A A V I X O U T D O O R S FOR SERVICE CALL USA 1 866 591 8921...

Страница 2: ...l cannot cover all possible conditions and situations that may occur It must be understood by the operator that common sense and caution are factors which cannot be built into this product but must be...

Страница 3: ...pressor use and care a Do not use the compressor if the power Switch does not turn it on and off Any compressor that cannot be controlled with the power Switch is dangerous and must be repaired b Disc...

Страница 4: ...hever is greater 10 Industrial applications must follow OSHA guidelines 11 Maintain labels and nameplates on the compressor These carry important safety information If unreadable or missing contact ou...

Страница 5: ...w the compressor to operate unattended HOW TO PREVENT IT Always remain in attendance with the product when it is operating Always turn off and unplug unit when not in use Do not leave compressor unatt...

Страница 6: ...k of injury to consumers Your compressor air tank must be removed from service by the end of the year shown on your tank warning label The following conditions could lead to a weakening of the air tan...

Страница 7: ...TO PREVENT IT Never operate the compressor outdoors when it is raining or in wet conditions Never operate compressor with protective covers removed or damaged 2 WHAT CAN HAPPEN Repairs attempted by un...

Страница 8: ...parts such as the pulley flywheel and belt can cause serious injury if they come into contact with you or your clothing HOW TO PREVENT IT Never operate the compressor with guards or covers which are d...

Страница 9: ...der some conditions and duration of use noise from this product may contribute to hearing loss HOW TO PREVENT IT Always wear proper hearing protection during use 27 AIR RECEIVER Over pressurizing the...

Страница 10: ...esulting in power loss to the motor and overheating Instead of using an extension cord increase the working reach of the air hose by attaching another length of hose to its end Attach additional lengt...

Страница 11: ...YOUR UNIT Compare the illustrations with your unit to familiarize yourself with the location of various controls and adjustments Save this manual for future reference 1 Power Switch 2 Reset Button 3...

Страница 12: ...for this fan to blow air through the vent holes in large amounts You know that the cooling system is working when air is being expelled Air Compressor Pump not shown Compresses air into the air tank...

Страница 13: ...cated at least 12 30 5 cm away from the wall or other obstructions that will interfere with the flow of air The air compressor pump and shroud are designed to allow for proper cooling The ventilation...

Страница 14: ...ces Do not modify the plug provided if it will not fit the outlet have the proper outlet installed by a qualified electrician 7 Improper connection of the equipment grounding conductor can result in a...

Страница 15: ...ilter or a dryer all not provided as shown on Figure A and Figure B Consult your air tool s manual for needed accessories A Portable Air Supply Setup A Air Hose Connects air to tool B Filter Prevents...

Страница 16: ...of use H Air Hose Connects air to tool I Filter Prevents dirt and condensation from damaging tool or workpiece J Regulator Adjusts air pressure to tool K Lubricator optional For air tool lubrication L...

Страница 17: ...ies The regulator outlet pressure must never exceed the maximum pressure rating NOTE Risk of property damage Compressed air from the unit may contain water condensation and oil mist Do not spray unfil...

Страница 18: ...pressure switch The Compressor will turn on automatically when the air pressure drops to 85 PSI and will turn off automatically when the air pressure reaches 100 PSI WARNING TO PREVENT SERIOUS INJURY...

Страница 19: ...otor Overload Protector Automatic Shut Off System not shown The motor has a thermal overload protector If the motor overheats for any reason the overload protector will shut off the motor The motor mu...

Страница 20: ...mpressor NOTE The environment in which the compressor is used and the frequency of use can affect how often you will need to check the Air Compressor components and perform maintenance procedures DAIL...

Страница 21: ...Operation Air tanks contain high pressure air Keep face and other body parts away from outlet of drain Use ANSI Z87 1 eye protection CAN CSA Z94 3 when draining as debris can be kicked up into face W...

Страница 22: ...arts Personal injuries can occur Before performing any maintenance or repair disconnect power source from the compressor and bleed off all air pressure and allow the air compressor to cool 1 Release a...

Страница 23: ...ee To Drain Tank under Maintenance WARNING Water will condense in the air tank If not drained water will corrode and weaken the air tank causing a risk of air tank rupture 3 Protect the electrical cor...

Страница 24: ...urely Disconnect the other electrical appliances from circuit or operate the compressor on its own branch circuit Check the extension cord Check wiring connection inside terminal box 3 Incorrect power...

Страница 25: ...t start up again on its own See Motor Overload Protector in OPERATION section contact a trained service technician 5 Loose fittings 5 Reduce air pressure then check all fittings with a soap solution f...

Страница 26: ...lace with wider hose and or hose connections 9 High altitude reducing air output 9 Higher altitudes require compressors with greater output 10 Pressure switch adjusted too low or 10 Make necessary adj...

Страница 27: ...ion cord or eliminate extension cord See Recommended Wire Gauge for Extension Cords 6 Dirty compressor head cylinder intercooler 6 Clean with compressed air 7 Operating pressure too high 7 Reduce oper...

Страница 28: ...Excessive tank pressure safety valve pops off 1 Safety valve needs service 1 Pull on test ring of safety valve If it still pops replace 2 Pressure switch does not shut off motor when compressor reache...

Страница 29: ...01 44 13 Plain Washer 1 A12101 13 45 Bolt 4 A12101 45 14 Fan 1 A12101 14 46 Bolt 3 A12101 46 15 Screw 2 A12101 15 47 Plain Washer 3 A12101 47 16 Ground Wire 1 A12101 16 48 Pressure Switch 1 A12101 48...

Страница 30: ...30 EXPLODED VIEW...