Description

GENERAL

The Powerex Oilless Rotary Scroll Air Compressor has advanced 

scroll compressor technology through the development of a 

completely oilless compressor. The Powerex Scroll Compressor offers a 

dynamically balanced air end which insures vibration-free operation. 

The rotary design permits a continuous 100% duty cycle.
Other standard features on the Powerex Scroll Compressor include: 

a Magnetic Starter, Motor Overload Protection, a High Temperature 

Shutdown Switch, an Air Cooled Aftercooler and a Single Phase or 

Three Phase 4 Pole ODP motor.

Safety Guidelines

A SEPARATE SAFETY BOOKLET IS PROVIDED ALONG WITH THIS 

MANUAL. READ AND UNDERSTAND The SAFETY BOOKLET. 

This manual contains information that is very important to know 

and   understand. This information is provided for SAFETY and to 

PREVENT EQUIPMENT PROBLEMS. To help recognize this information, 

observe the following symbols. MAKE SURE EVRYONE OPERATING OR 

SERVICING THE COMPRESSOR READS AND UNDERSTANDS ALL The 

INFORMATION PROVIDED.

Danger indicates an imminently  

  hazardous situation which, if not avoided, WILL 

result in death or serious injury.

Warning indicates a potentially  

  hazardous situation which, if not avoided, COULD 

result in death or serious injury.

Caution indicates a potentially 
minor or moderate injury.

Installation

INSTALLATION SITE

1.  The scroll compressor must be located in a clean, well lit 

and well ventilated area.

2.  The area should be free of excessive dust, toxic or flammable 

gases,  moisture, water, and direct sunlight.

3.  Never install the compressor where the ambient temperature is 

higher than 104

o

 F or where humidity is high.

4.  Clearance must allow for safe, effective inspection and 

maintenance. 20 inches of clearance for sides is recommended.

Installation (Continued)

5.  If necessary, use metal shims or leveling pads to level the 

compressor. Never use wood to shim the compressor.

Specifications

Product

SES Series Powerex Simplex Air Compressors

Performance  

Specifications

See Page 2

Lubrication

Grease-filled Bearing

Operating Voltages

1Ø 

230 Volts, 60 Hz; 230 Volts, 50 Hz

3Ø 

208-230/460/575 Volts, 60 Hz

Compression Cycle

Scroll

Motor Overload  

Protection

IEC Motor Overload Relay

Pressure Settings

Cut-In: 95 psig 

Cut-Out: 115 psig

Cut-In: 115 psig 

Cut-Out: 145 psig 

(High Pressure Unit)

Overpressure  

Protection

ASME Safety Valve Factory Set and Sealed

Outlet Air  

Connections

3/8 inch NPT

Tank Size

13 Gallon ASME Rated 175 psig

California Ordinance 

462 (L) (2)

Meets Requirements of this Ordinance

Tank Isolation

Standard All Units

Drive

3V Belt

Control Panel

UL508A Listed

Содержание SES02

Страница 1: ...e following symbols MAKE SURE EVRYONE OPERATING OR SERVICING THE COMPRESSOR READS AND UNDERSTANDS ALL The INFORMATION PROVIDED Danger indicates an imminently hazardous situation which if not avoided WILL result in death or serious injury Warning indicates a potentially hazardous situation which if not avoided COULD result in death or serious injury Caution indicates a potentially minor or moderate...

Страница 2: ...ng site Under some conditions the intake piping may facilitate the condensation of humidity in the intake air stream into liquid water The intake filters supplied by Powerex will not stop ingestion of liquid water by the pumps Liquid water going into the pumps will damage the pumps and void the warranty Always install drip legs with sufficient capacity to capture liquid water in the intake piping ...

Страница 3: ...scharge pressure gauge 10 Check the operation of the pressure switch by opening the outlet valve and confirming the compressor starts at approximately 95 psig for low pressure units and 115 psig or high pressure units DAILY OPERATION 1 Stop the compressor by turning switch to the OFF position NOTE If the compressor rotates in reverse for more than five seconds the check valve needs to be cleaned o...

Страница 4: ...30 31 32 33 34 35 36 37 38 39 40 41 42 43 54 44 53 45 46 47 49 50 51 4 X DIA 0 50 3 8 INCH FNPT AIR OUTLET 1 4 INCH FNPT TANK DRAIN MAIN POWER INLET 52 Scroll Unit Parts Breakdown Models SES02 SES12 SES03 SES13 SES05 SES15 SF120_PHA and SF130_PHA 2 HP 5 HP Scroll Enclosure Air Compressors Figure 2 ...

Страница 5: ... 90 push connect ST119702AV ST119702AV ST119702AV 1 21 1 4 inch drain tube PS010300AV PS010300AV PS010300AV 2 0 ft 22 Corner angle ST185500AV ST185500AV ST185500AV 4 23 Temperature switch 115 psi AM003033AV AM003033AV AM003033AV 1 Temperature switch 145 psi AM003034AV AM003034AV AM003034AV 1 24 Sub panel SL305300AV SL305300AV SL305300AV 1 25 1 4 inch bulk head fitting PS006701AV PS006701AV PS00670...

Страница 6: ...8 19 20 21 22 23 24 19 26 25 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 54 44 53 45 46 47 49 50 51 4 X DIA 0 50 3 8 INCH FNPT AIR OUTLET 1 4 INCH FNPT TANK DRAIN MAIN POWER INLET 52 Scroll Unit Parts Breakdown Models SES02 SES12 SES03 SES13 SES05 SES15 SF120_PHA and SF130_PHA Figure 2 Continued ...

Страница 7: ...daptor plate gasket IP088200AV IP088200AV IP088200AV 1 52 1 4 20 screw ST074003AV ST074003AV ST074003AV 8 53 3 8 inch PTFE tube PS001800AV PS001800AV PS001800AV 1 ft 54 3 8 x 3 8 x 90 push connect ST119705AV ST119705AV ST119705AV 2 Parts unique to SF120_PHA SF130_PHA 2 13 gallon tank AR234800LN AR234800LN 1 3 Deep base SL305401AV SL305401AV 1 18 Motor pulley 50 Hz PU202623AV PU202626AV 1 35 Motor ...

Страница 8: ...s for 145 psig units V belt Inspect Replace Readjust Temperature Sensor Confirm operation Pressure Switch Confirm operation Magnetic Starter Inspect Replace if contact point is deteriorated Safety Valve Confirm operation Pressure Gauge Inspect Ventilation Fan Inspect Replace if malfunctions Inspect Replace Notes 1 Inspect and perform maintenance periodically according to maintenance schedule 2 The...

Страница 9: ...9 2 HP 5 HP Scroll Enclosure Air Compressors Maintenance Log Date Maintenance Required Maintenance Performed ...

Страница 10: ...10 2 HP 5 HP Scroll Enclosure Air Compressors Electrical Diagram Single Phase Units 230 Volts Figure 3 ...

Страница 11: ...11 2 HP 5 HP Scroll Enclosure Air Compressors Electrical Diagram Three Phase Units 208 230 460 575 Volts Figure 4 ...

Страница 12: ... PE000210AV PS005834AV JP007716AV SES03084 460V 3P PE000101AV PE000204AV PS005834AV JP007702AV SES03085 575V 3P PE000101AV PE000203AV PS005847AV JP007702AV SES13086 230V 1P PE000103AV PE000207AV PS005834AV JP007716AV SF13087 230V 1P PE000102AV PE000207AV PS005834AV JP007716AV SF13085 230V 1P PE000102AV PE000207AV JP007716AV SF13097 230V 1P PE000103AV PE000208AV JP007716AV CW207560AV SF13095 230V 1...

Страница 13: ...tip seals 5 Replace tank drain 6 Correct power connections 7 Check discharge piping Excessive noise or vibration 1 Drive belt has separated or flat spot 2 Motor has failed 3 Pump is damaged 4 Cooling air fan is touching fan guard 1 Replace drive belt 2 Replace motor 3 Fix or replace pump 4 Check air fan daily Compressor shuts down on high temperature 1 Room temperature is above 104 F 2 Inlet air d...

Страница 14: ...14 2 HP 5 HP Scroll Enclosure Air Compressors Notes ...

Страница 15: ...r any replacement Air End or Vacuum Pumps installed on a Powerex manufactured system or unit after any initial warranty period has expired or where another warranty does not apply for any reason Powerex warrants that the Air End or Vacuum Pumps shall be free of Defects for a period of thirty six 36 months from the date of shipment by Powerex or ten thousand 10 000 hours of use whichever comes firs...

Страница 16: ...lation and use will comply with them Claims Any non warranty claims pertaining to the Products must be filed with Powerex within 6 months of the invoice date or they will not be honored Prices discounts and terms are subject to change without notice or as stipulated in specific Product quotations Powerex shall not be liable for any delay or failure arising out of acts of the public enemy fire floo...

Отзывы: