2 HP - 5 HP Scroll Enclosure Air Compressors
Maintenance Schedule (see Pump Manual for “How To” Instructions)
Operating Hours
Item
Action needed
500
2500
5000
10,000
20,000
Remarks
Receiver
Drain moisture
Daily
If equiped with an Electric
Drain, test daily
Cartridge Filter
Clean, Replace
●
▲
Part # ST073921AV
Ventilation Screen
Clean
●
Blower Fan
Clean
●
Fan Duct
Clean
●
Compressor Fins
Clean
●
Compressor
Regrease
▲
(Every 5000
hours for 145
psig units)
▲
▲
Use genuine Powerex grease
Tip Seal Set
Replace
▲
(Every 5000
hours for 145
psig units)
▲
▲
Heat Insulation Pipe
Replace
▲
(Every 5000
hours for 145
psig units)
▲
▲
V-belt
Inspect, Replace
Readjust
●
▲
▲
▲
Temperature Sensor
Confirm operation
●
Pressure Switch
Confirm operation
●
Magnetic Starter
Inspect
●
Replace if contact point is
deteriorated
Safety Valve
Confirm operation
●
Pressure Gauge
Inspect
●
Ventilation Fan
Inspect
●
Replace if malfunctions
●
Inspect
▲
Replace
Notes:
1. Inspect and perform maintenance periodically according to maintenance schedule.
2. The maintenance schedule relates to the normal operating conditions. If the circumstances and load condition
are adverse, shorten the interval time and perform maintenance accordingly.
3. Marked “Readjust” means the tension of the V-belt should be adjusted during the initial stage and inspected every 2,500
hours afterwards; 57-65 lbs initially, then 45-50 lbs after run-in.